Why glass slab is not used for manipulation of GIC?

Why glass slab is not used for manipulation of GIC?

According to the results of this study, RMGICs must not be manipulated on glass slabs, because there was a reduction in fluoride release.

Why do we use plastic spatula for mixing GIC?

The Glass ionomer powder is powdered glass. If you use a metal spatula some of the metal will be abraded off into your mix. This will make it grey.

Why Vaseline is applied over GIC?

Conclusion: Application of varnish over GIC can severely impede its fluoride release property. We suggest that in situations where the fluoride release property is more important than other properties it is better to coat the GIC with petroleum jelly or leave the restoration without any coating.

How does GIC bond to enamel?

Bond strengths are typically higher to enamel than to dentine, which suggests that the bonding takes place to the mineral phase [47]. Adhesion then develops rapidly, due to the formation of hydrogen bonds between the free carboxyl groups of the cement and the bound water on the surface of the tooth [48].

Which agent holds two things together?

A binder or binding agent is any material or substance that holds or draws other materials together to form a cohesive whole mechanically, chemically, by adhesion or cohesion.

How does GIC bond to tooth?

As a restorative material, GIC bond to the enamel and dentin via ionic and polar bonds, and the intimate molecular contact facilitates ion exchange of fluoride with the hydroxyl ions in the apatite of the surrounding enamel5,39.

What is Miracle mix?

Miracle Mix is a silver alloy reinforced glass ionomer restorative developed for use as a core build-up and transitional restorative material for clinical situations where high radiopacity and a strong colour contrast is preferred.

How do you do a GIC restoration?

The amount of tooth removal required for a GIC restoration: leaving some infected dentin and all the affected dentin in the cavity preparation. A cavity prepared for a composite resin restoration requiring removal of all infected and affected dentin to achieve a reliable adhesive base.

What is a cement spatula?

Cement spatula is used for mixing cements and powder in dental work. GDC provides cement spatula hand instrument in single end and in double end also. GDC provides cement spatula hand instrument in single end and in double end also.

How does GIC bond to dentin?

Both types of glass ionomer cements are adhesive to enamel and dentin via ionic bonding of the glass ionomer to the calcium and phosphate ions of the tooth.

How does GIC bond to composite?

It is recommended that a bonding adhesive be applied after acid etching chemically curing GICs in order to achieve a bond to composite resin. The light curing GIC should not be etched with phosphoric acid and is the material of choice as it is both stronger and less technique sensitive than the chemically curing GICs.

What are the different types of GIC cement?

Clinical Uses for GIC Type I cement: luting agent or liner The film thickness is 20µm. Type II cement: Class V erosion/caries Temporary rest (caries control) Class II, III, IV (dentin margins) The film thickness is 45µm. 33. Type III cement: Pit & Fissure sealant.

What makes glass ionomer cement unusual of GIC?

CONTENTS INTRODUCTION COMPOSITION CLASSIFICATION MANIPULATION OF THE MATERIAL SETTING MECHANISM APPLICATION OF MATERIAL & USES ADVANTAGES & DISADVANTAGES PROPERTIES MODIFICATIONS & ADVANCEMENT IN MATERIAL CONCLUSION REFERENCES 3. your name What is unusual of GIC???

What kind of adhesive relationship does GIC have with enamel?

GICs have good adhesive relations with tooth substrates, uniquely chemically bonding to dentine and, to a lesser extend, to enamel.

How does GIC bond to the tooth structure?

Bonding TO Tooth Structure GIC share the adhesive potential of the polycarboxylate cement. They appear to bond primarily to the inorganic component (Ca) of the tooth st. by initial hydrogen bonding, forming a metal ion bridges.

What to do with a mixing and loading pad?

Install sloping approach ramps (aprons) at vehicle entrances to minimize dust and trash accumulation on the mixing and loading pad. This also prevents surface water from the surrounding area from flowing onto the mixing and loading pad.

Clinical Uses for GIC Type I cement: luting agent or liner The film thickness is 20µm. Type II cement: Class V erosion/caries Temporary rest (caries control) Class II, III, IV (dentin margins) The film thickness is 45µm. 33. Type III cement: Pit & Fissure sealant.

When to use glass ionomer cement after mixing?

The material should be used as soon as possible after mixing since its viscosity increases and will reach a stage where the material is unworkable. 10. 2-GLAss iOnOmER CEmEnT mixinGRequir ements:Powder & Liquid, Glass slab or Non absorbable Treated paper pad & plastic or ceramic spatula.•

Who is the mixing and loading pad professor?

David W. Kammel, Professor, Biological Systems Engineering Department, University of Wisconsin Cooperative Extension The mixing and loading pad is the main operational area of the pesticide and fertilizer storage facility.